HSR works using active microwave technology and image analysis within the inspection area:
  1. In reflection mode, HSR scans the human body using scattered and reflected microwave signals. It reconstructs an image and analyzes the dielectric properties of detected objects to identify potential explosive devices (EDs).
  2. In transmission mode, microwaves pass directly between the two pillars as a person walks through. This provides additional data on items carried on the body or in backpacks.
HSR also includes passive magnetic sensors to detect metal objects.
The system has two built-in front cameras to monitor movement within the inspection zone, and one side camera on a pillar. If a suspicious object is detected, the side camera captures a photo as the person exits the portal.
When a threat is identified, an alert is sent to the operator’s computer via the HSR Client software. The alert includes a photo of the person and an estimated location of the object on the body. The warning is supported by a sound or vibration to get the operator’s attention.


    • Related Articles

    • HSS.2A PRINCIPLE OF OPERATION

      The HSS system uses radio waves and cameras to automatically detect hidden threat objects on a person or in their belongings. It creates an image of the person using radio waves. Detects suspicious items and compares them to known threats (like ...
    • HSR.4B INSTALLATION SITE REQUIREMENTS

      Location: Minimum space: 5.0 m (L) × 4.1 m (W) × 3.0 m (H) Must allow installation of deflectors on HSR pillars No floor or nearby vibrations No direct sunlight on video cameras No large static/moving metal objects within 3 m of the system No foreign ...
    • HSR.4B GENERAL INFORMATION

      The Human Security Radar (HSR) is an Active Microwave System developed by APSTEC. It is designed for non-contact inspection of people to detect metal and dielectric (non-metallic) objects hidden under clothing or in backpacks. Essential information ...
    • HSR.4B COMPONENTS

      Component Quality Pillar # 1, assembled with a decorative buffer bar 1 pc Pillar # 2, assembled with a decorative buffer bar 1 pc Cable duct arch with connection cables and central support 1 set Packaging 1 set Calibration and tuning kit 1 set ...
    • HSR.4B System Status and Errors

      Possible HSR Statuses The HSR system may operate in the following states: Connected – the system is functioning normally. Displayed in green without any additional messages. Disconnected – no connection between the computer and the HSR system. ...