HSS.2A RECEIVER PERFORMANCE CRITERION
The Service Interface software allows you to check how well the device receivers are working.
To do this, open the Scripts tab.
In the drop-down list, choose Blocking Test.
You can run the test separately for each pillar.
Choose the required pillar (1 or 2) from the list, then click Run script.
A warning message will appear saying that the test will stop normal system operation.
Click Confirm to continue.
The system checks the signal quality at the receivers by measuring the distance between the transmitter and receiver.
The expected standard distance is 126 cm.
If the result differs by more than 10% (i.e. less than 113.5 cm or more than 138.5 cm), it may indicate a problem.
If the result is within this range, the receivers are working correctly.
Related Articles
HSS.2A ASSEMBLING
The HSS is intended for stationary installation and must be placed at a location approved by the APSTEC technical team. Installation should be carried out only by trained personnel, either from the APSTEC technical team or an authorised organisation, ...
HSS.2A REPAIR,RECYCLING AND WARRANTY
1. Repairs must be carried out only by authorized specialists from Apstec Systems. For repair contacts, refer to the “Contact Information” section. 2. Disposal and recycling of the HSS system must follow local regulations for electronic and ...
HSS.2A POSSIBLE INSTALLATION SITES AND REQUIREMENTS
Suitable installation sites The HSS system is designed for fast and safe inspection of people in high-traffic areas. It can be installed in: Transport hubs such as airports, train and bus stations, metro stations Public events including concerts, ...
HSS.2A USAGE RECOMMENDATIONS
First Year of Operation After the first year, a qualified engineer should perform a full system inspection: Check all key components, including electronic and mechanical parts Inspect electrical connections for oxidation, looseness, or wear Test ...
HSS.2A STATUS CHANGE AND OPERATOR ACTIONS
The HSS does not make decisions. It alerts the operator to possible threats. All further actions must follow the organization's internal security procedures. Message Status description Operator’s Action Connected Green. System is operating normally ...