Apstec Merlin: Operating Conditions
Here is the breakdown of the environmental and operational requirements for the Merlin system.
📊 Operating Environment Parameters
Recommended Temperature Range: +3°C to +40°C
Maximum Temperature Range: -10°C to +55°C
Humidity: 5% to 90%, non-condensing
Atmospheric Pressure: 630 mmHg to 800 mmHg
🌡️ Peak Temperature Notice
The Merlin system is designed to operate reliably even under short-term peak temperature conditions. However, prolonged exposure to extreme temperatures may reduce the time between required maintenance services.
⚠️ Installation & Operational Notices
Authorized Setup: Installation, calibration, and activation of the Merlin system must be carried out only by APSTEC technical specialists, an authorised organisation, or trained personnel of the End User.
Compliance: The Merlin system must be operated strictly in accordance with the instructions provided in this User Manual.
Related Articles
Apstec Merlin: System Requirements
The Apstec Merlin system operates by generating a controlled magnetic field and measuring very small disturbances in that field caused by objects carried by a person. Because the system is designed to detect extremely weak magnetic signatures, it is ...
Apstec Merlin: System Overview & General Information
The Apstec Merlin system is a walk-through metal detector developed by APSTEC. It is designed for stand-off screening of pedestrian traffic to detect metal objects concealed under clothing or in personal belongings, helping to identify potential ...
How to Operate the Apstec Merlin?
1. System Initialization and Operating Modes The user can perform several actions to operate the Apstec Merlin system across different operational states: 🔌 Power On — Turns on the system from a powered-off state. After switching on, the system ...
How Should the Apstec Merlin System Be Repaired, Recycled, and Maintained?
🔧 Repair The Apstec Merlin system must be repaired only by authorized Apstec Systems personnel. Any unauthorized repair attempts may cause damage and void the warranty. ♻️ Recycling When the system reaches the end of its service life, it must be ...
HSR.4B OPERATING CONDITIONS
1. The HSR system is designed for indoor use only, in environments with controlled climate conditions. This protects the device from direct sunlight, rain, wind, sand, and dust from outside air. Humidity levels should also be controlled to prevent ...