HSS.2A SAFETY WARNINGS

HSS.2A SAFETY WARNINGS

Notes
Please read and keep these instructions. Failure to follow them may result in injury, malfunction, or damage to the device.

  1. Connect the device only to a properly grounded power outlet.
  2. Do not remove the grounding pin from the power plug.
  3. Make sure the system is fully assembled and correctly connected before switching it on.
  4. The use of a residual current device (RCD) with a 30mA rating is recommended for added safety.
  5. Use the system only as intended—improper use may compromise safety and performance.
  6. Follow the assembly and disassembly instructions carefully.Disconnect RF cables from both sides of the arch before dismantling.
  7. Maintain the temperature and humidity conditions specified in the manual.
  8. Avoid directing bright light at the system’s cameras.
  9. Inspect the device casing before turning it on.
  10. Do not use it if the casing is damaged.Set up the system only on a flat, level surface.
  11. Ensure a qualified professional verifies grounding at the installation site.
  12. If the system is moved, check the grounding again at the new location.
  13. Do not attempt to repair the system yourself—contact technical support.
  14. If the outer casing is damaged, immediately disconnect power.
  15. The casing provides protection against dust and moisture.
    • Related Articles

    • HSS.2A GENERAL INFORMATION

      Human Security Scanner (HSS) is a people-screening solution that uses microwave and passive magnetometry technologies to detect threats. It can identify explosives, narcotics, firearms, and metals carried on the body or in backpacks and handbags. ...
    • HSS.2A DIMENSIONS

      External dimensions - 2245 mm х 1341 mm х 580 mm Required minimal space for HSS installation - 1.8 m x 1.5 m Passage width - 1.2 m The Inspection zone of HSS system
    • HSS.2A STORAGE

      The HSS must be stored in indoor facilities that meet the conditions specified in Table. Parameter Value Air temperature -40°C to +55°С Humidity 5% to 90%, non-condensing Keep the HSS in a dry place. Do not turn the boxes over. Do not stack the ...
    • HSS.2A FUSE REPLACEMENT

      Fuses are replaceable components, but they are not part of regular maintenance. Under normal operation, the fuse should not need to be replaced. However, if the device stops working or fails to power on, the fuse may be blown and should be replaced. ...
    • HSS.2A SPECIFICATION

      PARAMETER VALUE Voltage 100 - 240 VAC, 50 - 60 Hz Rated input (AC) power 150 W Peak input (AC) power 250 W Net weight of HSS.2A system 90 kg IP rating IP54 External dimensions (See Fig. 1) 2245 mm х 1341 mm х 580 mm Required minimal space for HSS ...